Kidde KF30LL Interconnectable Heat Alarm with Long-Life Back-Up Battery
Image is for illustrative purposes only

Kidde KF30LL Interconnectable Heat Alarm with Long-Life Back-Up Battery

Part: KF30LL
Need this part urgently: we advise you to check the stock availability for this item by contacting our sales team on 01482 589015
Description
  • Mains-powered heat alarm that can be interlinked with up to 23 other Kidde mains alarms, be they ionisation, optical or heat.
  • Once interlinked, the detection of the relevant danger by an individual unit will sound across all the connected alarms.
  • Mains-powered heat alarms can be used throughout the home in humid or dusty environments where an optical or ionisation smoke alarm is unsuitable, e.g. kitchens, loft spaces and garages.
  • The Firex range requires installation by a professionally qualified electrician and complies with UK Building Regulations for new housing and associated standards (Grade D BS 5839, Part 6).
  • Interlink with up to 23 Firex hard-wired alarms – all alarms sound if danger is detected
  • Alarm memory – identifies source unit within interconnecting network
  • Combined Test/Hush button allows regular testing of alarm function and can be used to temporarily silence nuisance alarms
  • Auto reset after activation
  • Tamper-resistant locking device – prevents unauthorised removal without the use of a tool
  • Mains operation – 9V Lithium back-up battery supplied as standard

Model :KF30LL
Power Supply :230V mains-powered with 9V Lithium battery back-up
Temperature Range :0ºC to + 40ºC
Humidity Range :Up to 93% Relative Humidity (RH) non-condensing
Storage and Transport :-20ºC to +60ºC and 5–95% relative humidity (RH) non-condensing
Bracket Dimensions :127 x 127 x 39mm
Alarm Dimensions :133 x 133 x 6mm
Alarm Weight :213g
Warranty :6 years
Approvals :BSI certified to BS5446 Part 2 2003
 :CE tested and certified
Sensor :Thermistor (Thermal Resistor) within detection unit
Button Test :Simulates the effect of heat at the sensor, checks electronics and sounder
Automatic Self-test :Circuitry is tested and unit beeps (chirps) if fault is detected
Supply Voltage :230V AC, 50 Hz (nominal UK voltage)
Power Consumption :< 15mA
Connection :Push-in/snap-fit type connector with 150mm long flying leads (supplied)
Battery :Back-up User replaceable alkaline 9V battery (522/6LR61)
Power-on Indicator :Continuous green LED
Alarm Sounder :Electronic piezo-electric sounder (T3 pattern sound - three pulses - space - three pulses) with soldered contacts
Sound Output :85dB (A) minimum at 3 metres
Alarm Frequency :3.2 kHz typical
Alarm Status :Red LED flashes approx once every five minutes = normal operation
 :Red LED flashes once a second = sensing heat in excess of 58ºC (sounder alarm sounds)
Interconnection :Up to 24 Firex and Kidde ‘Slick’ units (smoke, heat and CO) can be hardwire interconnected with optional control (see below)
Optional :Controls Wired Remote Test and Hush Unit (REMTH) allows test and hush of interlinked units
Optional :Pattresses SMK23RU also has integral switchable relay for operating remote devices
 :SMK4896 – Surface mounting base for added ease of installation
Fixing :Mounting bracket ring supplied with two ‘T’ slot fitting option
 :57mm spacing to a maximum of 90mm for standard screw fittings on back boxes
 :Bracket has 50mm diameter central access hole for cabling
Plastics used :NORYL – Cover, main body and mounting bracket
 :Lead-Free Status All Firex alarms are lead-free